Commercial Restrooms: 5 Requirements That Are Not Optional in a Leased Space

The accessible fixture, the handwashing sink, the count, the air and the surfaces. Five requirements that a landlord cannot waive.

Commercial restroom with a wall-hung toilet, grab bars and a mirror
Illustration — a commercial restroom where every detail is a requirement, not a preference.

A leased restroom is the smallest room in the building and the one with the longest list of things that cannot be negotiated. The landlord may have opinions about the tile, the vanity is a design decision, and the access, the handwashing, the air and the surfaces are not opinions at all: they are requirements with a rule behind each one, and they are the requirements that get cited on an inspection.

1The accessible fixture, and the space around it

This is the requirement that surprises people, because it is not one fixture, it is a room: the accessible water closet with the grab bars, the lavatory with the clearance underneath it, and the turning space that lets somebody who uses a wheelchair turn around in it. The Standards set each of those dimensions and the clear floor space in front of every one of them. In a leased space the room is usually small and the layout is fixed by the existing walls, so the question is not whether to include the accessible fixture but how to fit one without shrinking something else the code also protects.

2The handwashing sink, and where the soap goes

The Food Code requires a handwashing sink in the areas where food is prepared and where the hands are washed, and it says what that sink has to be: it has to be supplied with running water, soap and a means to dry the hands, and it may not be used for anything else, including for dumping food or for the cleaning of equipment. In a leased suite that has no kitchen, the requirement moves to the plumbing code, and in every case the detail that gets missed is the same: the soap and the towels have to be there, mounted, and the sink has to be reachable from the door without crossing anything.

3The count of fixtures per occupant load

The number of fixtures is not a design choice, it is calculated from how many people the space is approved for, and the calculation comes from the plumbing code that applies to the building. This is the number that moves a commercial plan the most, because adding seats to a food space changes the occupant load, and the occupant load changes the number of fixtures the room has to have, and the room is the size it is. Hitting the count in an existing space is a plumbing and layout problem, and it is much cheaper to solve on the drawings than on the day the inspector arrives.

4The air, and where it goes

A restroom without an exhaust fan is a room that holds moisture and odor, and in a commercial space the ventilation has a requirement behind it: a local fan that exhausts outdoors removes the contaminants directly from the room where it is located and raises the outdoor air ventilation rate for the whole building. That fan has to discharge outdoors and not into the ceiling plenum, and in a leased space the duct may have to be routed through the building, which is a conversation with the landlord and with everybody above. The DOE covers the other half: what happens when the moist air of the room meets a colder surface somewhere it should not.

5The surfaces, and what they have to be able to take

The last requirement is the one that gets decided on a sample board and then costs money. The Food Code requires the floors, the floor coverings, the walls, the wall coverings and the ceilings to be designed, constructed and installed so that they are smooth and easily cleanable, and the utility service lines and pipes may not be unnecessarily exposed. In practice that means the floor and the wall finish, the coving at the junctures, the sealant at the corners and the surface of the partitions, and it is the requirement that decides whether a beautiful dark grout in a hospitality bathroom is going to survive a year of a janitor with a pressure washer.

How to plan a leased restroom

Two things, and both of them are about measuring before designing.

Measure the room and the door, and then the swings

The door swing, the clear floor space, the turning space and the clearance in front of every fixture have to exist at the same time, in the room you actually have. Ask for a scaled layout with the clearances marked, the way they get marked on an accessible design drawing, and check it against the plumbing locations in the existing walls, because moving a drain is a different project from moving a partition.

Ask what the building gives you

Ask what the building provides: the water heater, the waste line, the vent stack, the fan, the lighting circuit and the power for the fan. Every one of those is either there or it is a project, and in a leased space the cost of a new vent stack or a new electrical circuit can be larger than the cost of the room.

What to ask before the estimate

Two questions, and both of them are about the code path.

Which code governs this room

Ask whether the room is reviewed as part of a food establishment, in which case the Food Code plan submission has to carry the layout, the plumbing and the finish schedules, or as part of a general commercial space reviewed under the building code. The answer decides which drawings go in and which reviewer sees them.

What is in the lease about the restroom

Ask whether the landlord keeps the restroom or whether it comes with the suite, and what the restoration obligation is if it comes out. A restroom that the landlord owns is a room you are not designing, and a restroom that comes with the suite is a room you are designing, and the difference shows up in the estimate before anything is bought.

The 5 requirements

The requirementWhat it isThe rule behind it
The accessible fixtureThe water closet, the lavatory and the clearances around themThe 2010 ADA Standards
The handwashing sinkRunning water, soap, a way to dry, used for nothing elseThe Food Code and the plumbing code
The count of fixturesHow many for how many people the space is approved forThe plumbing code and the occupant load
The airA fan that discharges outdoors, not into the plenumThe ventilation rules and the lease
The surfacesSmooth, easily cleanable, coved and sealedThe Food Code and the janitor

Where this comes from

Five public documents: the accessibility standards, the food code, the sanitation rules and the ventilation.

Start with the ADA Standards. The accessible fixture and the clearances around it are the dimensions that decide whether the room works, and everything else fits around them.