Why a brand-new system can leave the house hot anyway — the sizing calculation it was bought on and the air the duct system actually delivers — for homeowners and property owners across Memphis, West Tennessee, North Mississippi & Eastern Arkansas.
A new system that will not cool the house is one of the most common complaints we get, and it is usually not the equipment. It is the two numbers that were never verified: the size the system was bought on, and the air the duct system delivers. Both are checkable before anyone signs off.
1What the house needed, against what got installed
The first number is the cooling load of the house — an engineering calculation of what the building actually requires, from how it is built and where it sits. The second half of the comparison is the unit that arrived. DOE’s right-sizing guidance is blunt that casual estimates based on floor area or on contractor habit produce systems that do not match the house, and that the sizing procedures the trade relies on are Manual J for the load and Manual S for the equipment chosen from it. If the two agree, the problem is somewhere else and you have eliminated a whole branch of causes. If they do not, no amount of refrigerant, filters or patience fixes it, because the system was never asked to cool this house.
2What the duct system actually delivers
Equipment is rated at the coil; the house gets whatever the duct system carries to it — the number nobody measures on a new install. ENERGY STAR’s duct-sealing guidance is that a substantial share of the air in the duct system is lost to leaks, holes and poorly connected joints, and that the symptoms are recognisable: bills that climbed after the install, rooms that will not cool, runs routed through an attic, crawlspace or garage, flex duct kinked in a tight chase. A brand-new system on old distribution performs like an old system, and adding capacity to compensate for lost airflow makes it worse.
What has to be on the sign-off sheet
A system that was never verified cannot be signed off. These checks belong on the handover paperwork.
The load calculation, and the unit chosen from it
Not a square footage rule and not the size of the unit that was already outside. The calculation for the house, and the unit selected from it.
Airflow and static pressure with the filter in place
Measured the way the system will run, with the filter the owner will use. A reading taken with the temporary filter still in the bag is not a reading.
The refrigerant charge verified at the unit
Set to the manufacturer’s specification for the equipment and the conditions, not topped up by feel. A system never commissioned correctly fails the same way again.
Every supply run and register connected and open
Including the ones nobody looks at: returns clear of stored items, transitions sealed, drain lines discharging where they should.
Permit pulled, inspection passed, warranties registered
The electrical service and disconnect verified, the permit and inspection closed out, and the warranty registrations handed over in writing.
If your new system is not cooling
Do this before you let anyone change the equipment.
Ask the installer in writing
A new system that does not hold its rated performance is the installer’s to answer, under the installation warranty. A written record turns a conversation into a claim, and it is the fastest way to a return visit.
Refrigerant is not the answer by default
EPA asks homeowners to have technicians locate and repair a leak rather than top off a low system. And a system starved for air can freeze its coil, which shortens the life of the compressor.
Questions we get before we sign off
Is my new AC too small?
It can be, and it is checkable. Compare the cooling load calculated for the house against the unit installed: if the unit is smaller than the load, it will not keep up on the hottest days.
Will a bigger unit fix it?
Usually not. A larger system fixes neither a duct system that cannot deliver the air nor a load calculation that was never done. Verify the calculation and the airflow first.
Who is responsible if the new system does not cool?
The installer, under the installation warranty, and the manufacturer under the equipment warranty. Both run on paperwork — the handover record and the registration.
Where this comes from
Every technical claim above traces to a public source: a federal guideline, a federal rule, or a government program.
- DOE / NREL — Measure Guideline: Air Conditioner Diagnostics — The commissioning checks behind a sign-off.
- DOE / Building America — Right-Size Heating and Cooling Equipment — Why equipment sized without a load calculation wears out faster.
- DOE — Consumer Guide to Home Heating and Cooling — The sizing question in homeowner terms.
- ENERGY STAR (EPA) — Duct Sealing — That a substantial share of the air in a duct system is lost.
- EPA — Homeowners and Consumers: Frequently Asked Questions — That technicians should locate and repair leaks, not top off.
A contractor who publishes a price table here would be quoting against a moving market. We publish the method instead, and price the work in writing for your property.
The same verification runs on every install we do. See our process →
Want the system signed off on paper?
We run the sizing and airflow verification before the job closes, and you get the readings in a written handover record. If the system you have is not cooling, tell us what it is doing.